orp electrical tds conductivity probe tester sensor monitor electrode For general

Product Details
Customization: Available
Type: Orp Electrode
Cooling System: Radiator
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
23
Year of Establishment
2018-01-10
  • orp electrical tds conductivity probe tester sensor monitor electrode For general
  • orp electrical tds conductivity probe tester sensor monitor electrode For general
  • orp electrical tds conductivity probe tester sensor monitor electrode For general
  • orp electrical tds conductivity probe tester sensor monitor electrode For general
  • orp electrical tds conductivity probe tester sensor monitor electrode For general
  • orp electrical tds conductivity probe tester sensor monitor electrode For general
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
CS2753C
Function
Over Voltage Protection, Overheat Protection, Short Circuit Protection
Materials
Plastic
ORP range
+/-1000mV
Temperature range
0-80 Degree
Pressure resistance
0-0.6MPa
TEMP sensor
NTC10K/NTC2.2K/PT100/PT1000
Housing material
PP
Double junction
Yes
Connection thread
NPT3/4′′
Cable length
10m standard or other
Sensitive membrane
PT
Connection method
Wire Boring Tin / Y Plug / Pin / BNC
Application range
For general chemical solutions
Transport Package
Carton Box
Specification
For General purpose, conventional solution
Trademark
CHUNYE
Origin
Shanghai, China
HS Code
9027
Production Capacity
2000PC/Month

Product Description

CS2753C ORP Sensor

The CS2753C is a versatile ORP electrode suitable for general chemical solutions.

Specification Details
ORP Range ±1000 mV
Temperature Range 0-80°C
Pressure Range 0-0.6 MPa
Temperature Sensor NTC10K/NTC2.2K/PT100/PT1000
Housing Material PP
Sensitive Membrane Pt
Mounting Thread NPT 3/4''
Cable Length 10 meters or as agreed
Cable Connector Pin, BNC, or as agreed

Installation and Usage Instructions:

  • Environment: Ensure the electrode is installed in a suitable environment for the chemical solutions being measured. Avoid exposure to incompatible substances.
  • Connection Method: Connect the electrode using the appropriate cable connector (Pin, BNC, or as agreed) to ensure proper signal transmission.
  • Temperature Sensor: Use the specified temperature sensors for accurate temperature compensation.

Maintenance and Care:

  • Regular Inspection: Periodically check the electrode for any signs of wear or damage to maintain optimal performance.
  • Cleaning: Clean the electrode as necessary to prevent buildup that could affect measurement accuracy.

After-Sales Service:

  • Warranty: 12 months from the date of purchase.
  • Maintenance Response Time: Maintenance is guaranteed within 7 working days, with a response time within 3 hours.
  • Technical Support: Lifetime free technical guidance and training is provided.

Order and Delivery Information:

  • Minimum Order Quantity: Generally 1 unit/piece.
  • Payment Methods: T/T, L/C (Typically, 100% T/T in advance, with the balance due before shipment).
  • Delivery Methods: Worldwide delivery from Shanghai via sea, air, truck, express, or combined transport.
  • Delivery Time: Typically 15 to 30 working days, depending on product type, order quantity, and special requirements.

Technical Service:

  • Contact: Contact us anytime for technical questions. Prompt responses and satisfactory answers are provided. On-site technical support overseas can be arranged if needed.

FAQ:

  • Are you a trading company or manufacturer? We are a factory.
  • How can I choose the suitable one? Please tell us your detailed requirements by mail or online, and we will recommend the suitable one as per your request.
  • Is your price competitive? We ensure to offer you the best quality at a competitive price.
  • What are your terms of payment? We accept 100% T/T in advance, with the balance due before shipment.
  • When will I receive it after payment? Normal models can be delivered within 3-7 days. Please contact us to check the transport time to your address.
  • How will it be delivered? We can send by Express, Sea, or Air.
  • Will it be damaged during transport? Please do not worry; we use standard export packaging to ensure safe delivery.
  • What should I do if I do not know how to use it? A user manual will be sent with the device, and you can also contact us for additional technical support.


Delivery:

orp electrical tds conductivity probe tester sensor monitor electrode For general


 
Company Profile

 

orp electrical tds conductivity probe tester sensor monitor electrode For general
     orp electrical tds conductivity probe tester sensor monitor electrode For generalorp electrical tds conductivity probe tester sensor monitor electrode For generalorp electrical tds conductivity probe tester sensor monitor electrode For generalorp electrical tds conductivity probe tester sensor monitor electrode For general
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More