T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter

Product Details
Customization: Available
After-sales Service: 1year
Warranty: 1year
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
23
Year of Establishment
2018-01-10
  • T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter
  • T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter
  • T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter
  • T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter
  • T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter
  • T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter
Find Similar Products

Basic Info.

Model NO.
T4200
Appliance
Food Analysis, Medical Research, Biochemistry
Portable
Non Portable
Certification
RoHS, CE, ISO9001
Type
Concentration Meter
Contact
Contact
Output Signal Type
Digital Type
Production Process
Integration
Material
Stainless Steel
IP Rating
IP68
Customized
Customized
Range
0~0.5m...5m...10m...200mH2o optional
Signal Output
4-20mA;0-5V;0.5-4.5V;0-10V;
Accuracy
0.5%F.S; 0.25%F.S
Peak flow rate
15m/s
Voltage
12~36VDC; 5VDC;10VDC 
Transport Package
Carton Box
Specification
105W*225H*150D(mm)
Trademark
Twinno
Origin
Shanghai, China
HS Code
9027
Production Capacity
500pieces/Month

Product Description

T4200&T4202 Electromagnetic Flowmeter




T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter

Overview:
Electromagnetic flowmeter measurement principle is according to Faraday electromagnetic induction law, it is mainly used to measure the volume flow rate of conductive liquid and slurry in closed pipe.The main components of the sensor are: measuring tube, electrode, exciting coil, iron core and magnetic yoke housing;Including acid, alkali, salt and other highly corrosive liquid.The product is widely used in petroleum, chemical, metallurgy, textile, food, pharmaceutical, paper and other industries as well as environmental protection, municipal management, water conservancy construction and other fields.
 

Features:

1. It is not affected by the fluid density, viscosity, temperature, pressure and electric rate; 
2. The open-flow parts in the measuring tube have low pressure loss and low requirements in the straight pipe section;
3. Nominal diameter dn6-dn2000 covers a wide range, and there are many choices of lining and electrode, which can meet the requirements of measuring a variety of conductive fluids;
4. The converter adopts programmable frequency low-frequency rectangular wave excitation, which improves the stability of flow measurement and reduces the power loss;
 5.The converter adopts 16-bit embedded microprocessor, full digital processing, fast computing speed, strong anti-interference ability, reliable measurement, high accuracy, flow measurement range up to 1500:1;
6. High definition backlit LCD display, full Chinese menu operation, easy to use, simple operation, easy to learn and understand;
7. With RS485 or RS232O digital communication signal output;
 8.It has the function of conductivity measurement, can distinguish whether the sensor is in air traffic control or not, and has the function of self-inspection and self-diagnosis.
 9.Using SMD device and surface mount (SMT) technology, the circuit reliability is high;
 10.It can be used in the corresponding explosion-proof occasions.

Main technical parameters:
Carried Standard
 
JB/T9248-1999
DN
 
4,6,10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400,450,500,600,700,800,900,1000,1200,1400,1600,1800,2000
Peak flow rate
 
15m/s
Accuracy DN15~DN600 Value0.3%(flow rate1m/s)3mm/s(flow  rate<1m/s)
DN700~DN3000 Value0.5%(flow rate0.8m/s)4mm/s(flow rate<10.8m/s)
Fluid conductivity ≥5μ s/cm
Nominal Pressure
 
1.6MPa 1.6MPa 1.0MPa 0.6MPa 4.0,6.3,10MPa
DN15~DN150 DN15~DN600 DN200~DN1000 DN1000~DN3000 special orders
Environmental temperature
 
Sensor -25ºC - +60ºC
Converters and integrators -10ºC - +60ºC
lining material Polytetrafluoroethylene, polyneoprene, polyurethane, polyperfluorinated ethylene propylene (F46)
Maximum fluid
temperature
Integrated
 
70ºC
split type Polyneoprene lining 80ºC;120ºC(Note when ordering)
Polyurethane lining 80ºC
Teflon lining 100ºC;150ºC(Note when ordering)
Polyperfluorinated ethylene-propylene (F46)
electrode material stainless steel 0Cr18Ni12M02Ti,Hasteley alloy B, titanium, tantalum, platinum/iridium
Protection
 
DN15~DN3000 Split type rubber or polyurethane lined sensor 1P65 or 1P68
ther sensors, integrated flow meters and separation converters 1P65
Spacing
(split type)
Converter distance sensor is generally not more than 100m



Corrosion resistance of electrode material
 
Materials Anti-corrosion properties
 
Molybdenum stainless steel
(0Cr18N12MO2Ti)
Application: domestic/industrial water, sewage, weak acid and alkali salt solution, concentrated nitric acid at room temperature
Not applicable: hydrofluoric acid, hydrochloric acid, chlorine, bromine, iodine and other media
Hardgrove
 B
Application: non-oxidizing acid and non-oxidizing hydrochloric acid with a certain concentration of hydrochloric acid, hydrofluoric acid and other non-oxidizing hydrochloric acid, with a concentration not less than 70% of sodium hydroxide and other lye
Not applicable: oxidizing acid such as nitric acid
Hardgrove
 C
Application: corrosion of oxidizing acid, such as nitric acid, mixed acid, or mixed medium of sulfuric acid; Resistant to oxidation
Sexual salts or environmental corrosion containing other oxidants. Such as higher than room temperature hypochlorite solution; Very good corrosion resistance to sea water. Not applicable: reducing acids and chlorides such as hydrochloric acid
Titanium
 Ti
Application: chloride, hypochlorite, sea water, oxidizing acid
Not applicable: reducing acid such as hydrochloric acid and sulfuric acid
Tantalum
 Ta
Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other most acid liquid, including boiling point of hydrochloric acid, nitric acid and
Sulfuric acid below 175ºC. Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid
Platinum
(Pt)
Various acids, bases and salts, excluding aqua regia
Note: due to the variety of media, corrosion is affected by temperature, concentration, flow rate and other complex factors, so this table is for reference only, users should make their own choice according to the actual situation. For general media, you can refer to the relevant anti-corrosion manual. For the medium with complex composition such as mixed acid, corrosion experiments should be carried out on the selected materials

The lining material should be selected according to the corrosion, wear and temperature of the tested medium
Materials Main performance
 
Application
 
Polyurethane
 
  1.  Good wear resistance
  2. Poor acid and alkaline resistance
<45ºC
Measure neutral wear of coal slurry, mud and pulp
Natural rubber
(soft rubber)
  1.  Good elasticity and wear resistance
  2. Resistant to general weak acid, weak base corrosion
<80ºC
Measure water and sewage
Acid resistant rubber (hard rubber)
  1.  It can withstand the corrosion of hydrochloric acid, acetic acid, oxalic acid, ammonia water, phosphoric acid, 50% sulfuric acid and sodium hydroxide (potassium) at room temperature
  2. Not resistant to corrosion by strong oxidant
-25ºC~+90ºC
Measure general acid, base, and salt solutions
chloroprene rubber
  1. Good elasticity and wear resistance
  2. Resistant to general low concentration of acid, alkali, salt solution corrosion, but not resistant to oxidation medium corrosion
<80ºC
Measure water, sewage, mud and pulp


fluoroplastic
PTFE
F-4(PTFE)
  1.  It is resistant to boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solvents
  2. Strong wear resistance and poor adhesion
-40ºC~+180ºC
Measure the concentration of acid, alkali and corrosive solution and health media
chloroethylene-propyleneF-46(PTFE)
  1. Media not resistant to PTFE
  2. Not resistant to fuming nitric acid, butyl lithium
As PTFE, it can be used for higher negative pressure
polyperfluoroalkanes
Oxygen radicals(PFA)
Chemical resistance is similar to FEP Media not resistant to FEP


 Range selection table of electromagnetic flowmeter:
Caliber(mm) Range (m3/h) Caliber(mm) Range (m3/h)
DN4 0.022~0.45 DN300 25.4~2500
DN6 0.05~1 DN350 34.6~3400
DN10 0.03~3 DN400 45.2~4500
DN15 0.03~6 DN450 57.2~5700
DN20 0.12~15 DN500 77.6~7000
DN25 0.18~20 DN600 101~10000
DN32 0.29~30 DN700 138~13000
DN40 0.45~45 DN800 180~18000
DN50 0.7~70 DN900 229~22000
DN65 1.19~120 DN1000 282~28000
DN80 1.8~180 DN1200 407~4000
DN100 2.28~280 DN1400 554.1~55000
DN125 4.41~440 DN1600 732.7~72000
DN150 6.36~640 DN1800 916~91000
DN200 11.3~1100 DN2000 1131~110000
DN250 17.6~1800 DN2200 1368.4~130000


FAQ:
1.Are you trading company or manufacturer ?
We are factory and we offer OEM services.


2.How can I choose the suitable one?
Please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
 
3.Does your price is competitive?
We make sure to offer you the best quality with competitive price.
 
4.What is your terms of payment?
We accept 100% T/T in advance,balance before shipment.
 .
5.When I receive it after pay?
Normal models can be delivered with 3-7days,
please contact us to check transport time to your address.
 
6.How to deliver?
We can send by Express, by Sea and by Air.
 
7.Is will be broken during transport?
Please do not worry, we do standard export package.
 
8.What should I do if I do not know how to use?
User manual will be sent together, you can also contact us with more technological support.


Contact Us:

Tina Jiang
Sales Department
 
Shanghai ChunYe Instrument Technology Co., Ltd
4th Floor, Building 6, No.166 Mindong Road, Pudong New District, Shanghai, China 201209
 
 
 
https://twinno.en.made-in-china.com/


Delivery and Packing:

T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter


T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter



Our company:


T4200&T4202 Plus flow meter Discount Sewage Split Electromagnetic Flow meter


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More