T9282C Online Phosphate Monitor
I. Overview
With the improvement of the specified standards of power plants and the requirements of desalination and water purification projects, the timeliness and accuracy of phosphate monitoring have also been greatly improved, especially the low phosphorus treatment technology that is basically implemented at present, and the accuracy of the measurement of the low content of phosphate is more important. The company launched the T9282C type phosphate analyser, using photoelectric metering dosing method, cold light source spectroscopic measurement, no dead volume reaction pool, thus ensuring the accuracy and reliability of the instrument measurement.
II. Characteristics and technical parameters
2.1 Features:
- Adopt photoelectric metering dosing method, accurate measurement;
- Cold light source spectroscopic measurement, extending the service life of the light source;
- Automatic adjustment of the light intensity of the light source, light source attenuation can also ensure the accuracy of the instrument measurement;
- Automatic control of reaction temperature, constant temperature measurement and calibration;
- Large-capacity memory, can save 5 years of measurement data;
- 7-inch touch type colour LCD screen, operation and display are more intuitive;
- 4-channel isolated current output, configurable to any channel, any range or PID;
- 4-channel relay output, which can be configured to over-limit alarm, broken sample alarm or system failure alarm;
- RS485 interface for remote data monitoring;
- Queryable curve and measurement alarm in any time period.
2.2 Main technical parameters:
- Measuring range: 0-50.0mg/L, expandable
- Instrument display value error: ±1%F.S
- Repeatability: not more than 1%
- Measurement cycle: minimum 20 minutes
- Stability: baseline drift: using blank calibration, does not affect the accuracy
- Chemical drift: no greater than 1% of readings/month (varies depending on reagent stability)
- Reagent type: 1 type
- Temperature sensor: PT100
- Temperature measurement range: (0.0~60.0)°C
- Temperature measurement accuracy: ± 0.5 ºC
- Temperature compensation range: (0.1~60.0)ºC
- Isolated output signal and load: 4~20mA(RL<500)
- Alarm contact capacity: normally open contact AC220V/3A, DC24V/5A
- Normal working conditions of the instrument:
ambient temperature: 0~45ºC
Relative humidity: not greater than 85%
- Sample conditions:
Flow rate: 100-300mL/min
Temperature: (5~50)ºC
Pressure: 14 KPa
Allowable solid content of water samples: no more than 5 microns (no gelatinous material is allowed to appear, no oil and grease)
- Power supply: AC220V ± 22V 50Hz ± 1Hz Power: 150W
- Instrument external dimensions: 720 × 460 × 300mm
- Instrument opening size: 665 × 410mm