CS5530HK Potentiostatic Residual Chlorine Sensor

Product Details
Customization: Available
Cooling System: Radiator
Materials: Stainless Steel
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
23
Year of Establishment
2018-01-10
  • CS5530HK Potentiostatic Residual Chlorine Sensor
  • CS5530HK Potentiostatic Residual Chlorine Sensor
  • CS5530HK Potentiostatic Residual Chlorine Sensor
  • CS5530HK Potentiostatic Residual Chlorine Sensor
  • CS5530HK Potentiostatic Residual Chlorine Sensor
  • CS5530HK Potentiostatic Residual Chlorine Sensor
Find Similar Products

Basic Info.

Model NO.
CS5530HK
Measure range
0-2.000 mg/L, 0-20.00 mg/L
Installation thread
PG 13.5
Housing Material
Glass
Transport Package
1 PCS/Carton
Specification
Length 120mm*Diameter 12.7mm
Trademark
Twinno
Origin
Shanghai, China
HS Code
9027
Production Capacity
2000PCS/Month

Product Description

CS5530HK Potentiostatic Residual Chlorine Sensor

CS5530HK Potentiostatic Residual Chlorine Sensor





Electrode principle characteristics:

Constant voltage principle electrode is used to measure residual chlorine or hypochlorous acid in water. The constant voltage measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential. It consists of two platinum electrodes and a reference electrode to form a micro current measurement system. The residual chlorine or hypochlorous acid in the water sample flowing through the measuring electrode will be consumed. Therefore, the water sample must be kept flowing continuously through the measuring electrode during measurement.

The constant voltage measurement method uses a secondary instrument to continuously and dynamically control the potential between the measuring electrodes, eliminating the inherent resistance and oxidation-reduction potential of the measured water sample, so that the electrode can measure the current signal and the measured water sample concentration A good linear relationship is formed between them, with a very stable zero point performance, ensuring accurate and reliable measurement.



The constant voltage electrode has a simple structure and a glass appearance. The front end of the online residual chlorine electrode is a glass bulb, which is easy to clean and replace. When measuring, it is necessary to ensure that the water flow rate through the residual chlorine measuring electrode is stable.



1. Power supply and output isolation design to ensure electrical safety

2. Built-in protection circuit for power supply and communication chip, strong anti-interference ability

3. With comprehensive protection circuit design, it can work reliably without additional isolation equipment

4. The circuit is built inside the electrode, which has good environmental tolerance and easier installation and operation

5. The communication protocol is simple and practical and extremely convenient to use

6. Output more electrode diagnostic information, more intelligent

7. The internal integrated memory can still memorize the stored calibration and setting information after power off

8. POM shell, strong corrosion resistance, PG13.5 thread, easy to install.




Application:
Drinking water: ensuring reliable disinfection
Food: to ensure food safety, sanitary bag and bottle methods
Public works: detection of residual chlorine
Pool water: efficient disinfectant
 
The electrodes can be calibrated in the office or laboratory, and replaced directly on site, without additional on-site calibration, which greatly facilitates later maintenance
Calibration information record is stored in electrode memory.



 
Model NO. CS5530HK
Measure material Double platinum ring/3 electrodes
Housing material Glass+POM
Waterproof grade IP68
Measurement range 0-2mg/L;0-10mg/L;0-20mg/L
Accuracy ±1%F.S
Pressure range ≤0.3Mpa
Temperature compensation NTC10K
Temperature range 0-80ºC
Calibration Water sample, chlorine-free water and standard liquid
Connection methods 4 core cable
Cable length Standard 10m cable or extended to 100m
Installation thread PG13.5
Application Tap water, pool water, etc


After Sales Service

* The warranty period is 12 months from commissioning acceptance date on. In addition, we supply 1 year warranty and lifelong free technical guiding and training.
* We guarantee the maintenance time no more than 7 working days and response time within 3 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.



FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, etc.
Payment terms: Generally, We accept 100% T/T in advance, balance before shipment.

What are the available delivery methods?
Our port location: Shanghai
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 15 ~ 30 days; test equipment or analyzer delivery date is around 3~7 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years after start up of the system.

How is the technical services on the product?
You are welcome to contact us any time if you have any technical question. We will response promptly and answer to your satisfaction. If required and necessary, Engineer available to service and provide technical support for machinery overseas.





Delivery and Packing:
CS5530HK Potentiostatic Residual Chlorine Sensor

CS5530HK Potentiostatic Residual Chlorine Sensor



Our company:

CS5530HK Potentiostatic Residual Chlorine Sensor
     CS5530HK Potentiostatic Residual Chlorine SensorCS5530HK Potentiostatic Residual Chlorine Sensor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More