Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement

Product Details
Customization: Available
Contact: Contact
Output Signal Type: Digital Type
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
23
Year of Establishment
2018-01-10
  • Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement
  • Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement
  • Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement
  • Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement
  • Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement
  • Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement
Find Similar Products

Basic Info.

Model NO.
CS1737D
Output Status
Normally Closed
Production Process
Integration
Probe Type
Electrode Type
IP Rating
IP68
Certification
ISO
Customized
Non-Customized
Installation Type
NPT3/4′′
Output Form
RS485 MODBUS RTU
Transport Package
Carton Box
Specification
Metallic antimony
Trademark
twinno
Origin
Shanghai, China
HS Code
9027809900
Production Capacity
2000PCS/Month

Product Description




Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement

 CS1737D Digital pH Sensor





Designed for Hydrofluoric acid environment. HF concentration>1000ppm

Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.


The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
 
  1. Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage
  2. The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of hydrofluoric acid environmental media.
  3. High-strength glass bulb design, the glass appearance is stronger.
  4. The electrode adopts low noise cable, the signal output is farther and more stable
  5. Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in hydrofluoric acid environment media.


 
Model No. CS1737D
Power/Outlet 9~36VDC/RS485 MODBUS RTU
Measure material Metallic antimony
Housing material PP
Waterproof grade IP68
Measurement range 2-12pH
Accuracy ±0.1pH
Pressure resistance ≤0.6Mpa
Temperature compensation NTC10K
Temperature range 0-80ºC
Calibration Sample calibration, standard liquid calibration
Connection methods 4 core cable
Cable length Standard 10m cable, can be extended to 100m
Installation thread NPT3/4''
Application Hydrofluoric acid > 1000ppm water


After Sales Service

* The warranty period is 12 months from commissioning acceptance date on. In addition, we supply 1 year warranty and lifelong free technical guiding and training.
* We guarantee the maintenance time no more than 7 working days and response time within 3 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.



FAQ

What is the mini order quantity?
MOQ: generally 1 unit/piece/set

What payment methods are supported?
Payment method: By T/T, L/C, etc.
Payment terms: Generally, We accept 100% T/T in advance, balance before shipment.

What are the available delivery methods?
Our port location: Shanghai
Delivering to: Worldwide
Delivering method: by sea, by air, by truck, by express, combined transportation

How long is the product date of delivery probably?
Delivery date differs with product type, order quantity, special requirement etc. Usually our big machine delivery date is around 15 ~ 30 days; test equipment or analyzer delivery date is around 3~7 days. Some products have stock, contact us anytime to get more information.

How long is the warranty period?
We warrants the plant supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years after start up of the system.

How is the technical services on the product?
You are welcome to contact us any time if you have any technical question. We will response promptly and answer to your satisfaction. If required and necessary, Engineer available to service and provide technical support for machinery overseas.


Delivery:


Digital RS485 pH Sensor For Hydrofluoric Acid Environment MeasurementDigital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement


Our company:
Digital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement

    Digital RS485 pH Sensor For Hydrofluoric Acid Environment MeasurementDigital RS485 pH Sensor For Hydrofluoric Acid Environment Measurement


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More